TESLA WALL CONNECTOR (GEN 3) Charger Ground Fault Circuit Interrupter Tripping
| CONF | DIAGNOSIS | ACTION |
|---|---|---|
|
85%
CONF
|
Wall Connector Cable Assembly
The charging cable and handle are subject to mechanical fatigue and environmental exposure. Moisture ingress in the charging handle or a breakdown of the cable's internal insulation creates a high-impedance path to ground, triggering the CCID safety trip during the charging handshake.
SKU: 1457303-00-B
|
|
|
15%
CONF
|
Tesla Wall Connector Unit
If the cable is intact, the internal current-sensing transformer (toroid) or the differential amplifier on the mainboard may have failed. This results in the unit incorrectly detecting a leakage current during its power-on self-test (POST) or when the contactors close to initiate high-current flow.
SKU: 1457768-02-G
|
DIY Repair Guide
Watch exactly how to replace the Wall Connector Cable Assembly.
// NOTICE:
This report is generated by an Agentic AI Engineer utilizing probabilistic modeling.
PartSniper is an automated parts recommender service. AI-generated results may not be correct. This data is not a substitute for professional engineering advice or manual inspection. Always verify part compatibility and disconnect power before any repair. PartSniper is not liable for inaccuracies, injury, or damage.