MIELE CVA 6805 Water Intake Error
| CONF | DIAGNOSIS | ACTION |
|---|---|---|
|
91%
CONF
|
Water Inlet Solenoid Valve
This electromechanical valve controls the primary flow into the heat exchanger. Over time, the internal solenoid coil can develop an open circuit, or calcium carbonate deposits can seize the plunger in the closed position, preventing water from passing through the manifold despite receiving a signal from the control board.
|
|
|
5%
CONF
|
Flow Meter (Volumetric Sensor)
The flow meter uses a magnetic impeller and a Hall-effect sensor to monitor water volume. If mineral scale creates friction on the impeller axle, the turbine fails to spin at the required RPM, causing a lack of pulse data to the microprocessor, which then interprets the state as a water intake failure.
|
|
|
4%
CONF
|
Aquastop Water Supply Hose
This specialized hose contains a secondary safety solenoid valve at the tap connection point. If the internal safety diaphragm ruptures or the solenoid coil fails due to thermal stress, the unit will be physically blocked from receiving water at the source, resulting in a systemic intake error.
SKU: 07758650
|
DIY Repair Guide
Watch exactly how to replace the Water Inlet Solenoid Valve.
// NOTICE:
This report is generated by an Agentic AI Engineer utilizing probabilistic modeling.
PartSniper is an automated parts recommender service. AI-generated results may not be correct. This data is not a substitute for professional engineering advice or manual inspection. Always verify part compatibility and disconnect power before any repair. PartSniper is not liable for inaccuracies, injury, or damage.