MAYTAG MHW5630HW Error
| CONF | DIAGNOSIS | PART MATCH | ACTION |
|---|---|---|---|
|
91%
CONF
|
Drain Pump Assembly
The drain pump is responsible for the mechanical evacuation of water through centrifugal force. F09 E01 indicates the pump is failing to move sufficient volume to trigger the pressure sensor's 'empty' state within the allotted time. Failure usually involves debris lodged in the impeller or the degradation of the pump motor's internal permanent magnet.
SKU: W11414052
|
|
CHECK PRICE |
|
5%
CONF
|
Water Level Pressure Switch
The pressure transducer translates air pressure from the water column into a digital signal for the control board. If the sensor's diaphragm is ruptured or the electronics are out of calibration, it will report a 'full' state even if the pump has successfully evacuated the drum, triggering the timeout error.
SKU: W11261303
|
CHECK PRICE | |
|
4%
CONF
|
Washer Drain Hose
A physical restriction in the corrugated drain hose increases back-pressure and reduces flow rate below the threshold required for the timed drain cycle. Kinks or internal clogs from foreign objects impede fluid dynamics, resulting in the control board sensing a slow or failed drain event.
|
|
CHECK PRICE |
DIY Repair Guide
Watch exactly how to replace the Drain Pump Assembly.