KENMORE SERIES 500 WASHER (110-SERIES) Wont Drain
| CONF | DIAGNOSIS | PART MATCH | ACTION |
|---|---|---|---|
|
86%
CONF
|
Drain Pump Assembly
The drain pump is an electromechanical component responsible for evacuating water via a high-speed impeller. Failure occurs when foreign debris migrates from the tub and jams the impeller, or when the motor windings overheat and fail. Replacing the assembly restores the mechanical force needed to overcome head pressure in the drain line.
|
|
|
|
9%
CONF
|
Lid Lock Assembly
The VMW platform requires a confirmed closed-and-locked signal from this assembly before the control board authorizes the drain and spin phase. If the internal solenoid or microswitch fails due to mechanical fatigue or moisture ingress, the cycle will stall indefinitely with water in the tub. This is a common failure point for the Series 500 logic sequence.
SKU: W11307244
|
|
|
|
5%
CONF
|
Drain Hose
Physical blockages from lint accumulation or small clothing items can create a total fluid obstruction within the corrugated hose. Additionally, if the hose is installed too deep into the standpipe, it can create a siphoning effect that disrupts the pressure sensor's ability to trigger the next cycle phase. Replacing the hose ensures a clear, correctly vented path for fluid discharge.
SKU: W10350413
|
|
DIY Repair Guide
Watch exactly how to replace the Drain Pump Assembly.